Skip to product information
1 of 1

Eaton Bussmann

Bussmann EVH-125 | 125A 70VDC Fuse, 6kA AIC, MEGA Footprint

Bussmann EVH-125 | 125A 70VDC Fuse, 6kA AIC, MEGA Footprint

Regular price $10.98
Regular price Sale price $10.98
Sale Sold out
Shipping calculated at checkout.

The Eaton Bussmann EVH-125 is a 125 A bolt-down DC fuse rated 70 VDC with a 6,000 A interrupting rating, built to the ISO 20934 Type SF51 footprint — the same bolt pattern as a standard MEGA fuse. It drops into an existing MEGA position while more than doubling the voltage rating and tripling the breaking capacity. UL certified.

Why the 70 VDC rating matters

Most MEGA-format fuses are rated 32 VDC. A 48 V nominal LiFePO₄ bank charges to 58.4 V — well above that rating. DC faults have no zero-crossing to help quench the arc, so a fuse asked to interrupt above its rated voltage may not clear the fault. The EVH is rated 70 VDC, which covers 12 V, 24 V and 48 V nominal systems with margin.

Interrupting capacity and lithium banks

The 2025 revision to ABYC E-11 sets the interrupting-capacity requirement for lithium-ion batteries at 5,000 A for every 100 Ah of capacity, and calls for overcurrent protection at each individual battery on banks above 500 Ah. On that basis a 6,000 A device covers a single battery of roughly 120 Ah or less, and suits the per-battery position inside a larger bank. Main protection on a large bank still belongs to a Class T fuse sized to the whole bank.

These figures reflect our reading of the 2025 revision and are given for general guidance. Confirm the requirement against the current published standard for your application.

Specifications

Rated current 125 A
Rated voltage 70 VDC
Interrupting rating 6,000 A @ 70 VDC (TC = 2 ± 0.5 ms)
Bolt size M8 (8.55 mm holes)
Certification UL certified
Max voltage drop 110 mV at rated current
Pre-arcing I²t 57,000 A²s
Total I²t 68,400 A²s
Recommended conductor 16 mm² (approx. 6 AWG)
Operating temperature −40 °C to +125 °C
Housing / terminals PPA / matt tin-plated copper
Standard reference ISO 20934-2019 Type SF51
Compliance RoHS and ELV

Installation

  • Bolt centres 50.9 mm, overall length 68 mm, body height 9.9 mm — standard MEGA spacing.
  • M8 terminal bolts. Torque to 20 N·m ±1. Do not overtorque; the terminals are tin-plated copper.
  • Holds 100% of rated current for at least 4 hours. Opens in 1–15 s at 200% of rating and 0.3–5 s at 350%.

Typical applications

Battery-to-busbar protection on a single lithium battery up to about 120 Ah, per-battery protection inside a larger bank, DC-DC charger and alternator circuits, solar charge controller output, and any 48 V branch presently protected by a 32 V MEGA fuse.

This is not a substitute for a Class T fuse as the main overcurrent device on lithium banks above roughly 120 Ah, where the required interrupting capacity exceeds 6,000 A.

Not sure which rating you need? Jonsson Tech designs, installs and commissions these systems — send us your one-line and we will check it before you order.