Bussmann EVH Series 70VDC Fuses - Selection Guide

The Eaton Bussmann EVH series is a range of UL certified bolt-down DC fuses rated 70 VDC from 60 A to 500 A, all with a 6,000 A interrupting rating. They are built to the ISO 20934 Type SF51 footprint — the same 50.9 mm bolt spacing as a conventional MEGA fuse — so they drop into existing MEGA positions while more than doubling the voltage rating and tripling the breaking capacity.

Use the selection table below to pick a rating, then order the individual fuse. We stock the M8 bolt version (EVH-XXX part numbers).

Why the 70 VDC rating matters

Most MEGA-format fuses are rated 32 VDC. A 48 V nominal LiFePO₄ bank charges to 58.4 V — well above that rating. DC faults have no zero-crossing to help quench the arc, so a fuse asked to interrupt above its rated voltage may not clear the fault. A 32 V MEGA on a 48 V bank is one of the most common quiet mistakes in DIY lithium installs. The EVH's 70 VDC rating covers 12 V, 24 V and 48 V nominal systems with margin.

We wrote this up in more detail here: Your 48V Lithium System Probably Has a 32V Fuse In It.

Sizing interrupting capacity for lithium

The 2025 revision to ABYC E-11 sets the interrupting-capacity requirement for lithium-ion batteries at 5,000 A for every 100 Ah of capacity, and calls for overcurrent protection at each individual battery on banks above 500 Ah. On that basis a 6,000 A device covers a single battery of roughly 120 Ah or less, and the EVH is well suited to that per-battery position inside a larger bank. Main protection on a large bank still belongs to a Class T fuse sized to the whole bank.

Ampere rating and interrupting rating are separate questions. A 500 A EVH still only interrupts 6,000 A — picking a bigger fuse does not buy you more fault-clearing capacity.

These figures reflect our reading of the 2025 revision and are given for general guidance. Confirm the requirement against the current published standard for your application.

Selection table

Rating Conductor Max V-drop Pre-arcing I²t Total I²t
60 A 6 mm² (10 AWG) 110 mV 7,000 8,400
80 A 10 mm² (8 AWG) 110 mV 19,000 22,800
100 A 10 mm² (8 AWG) 110 mV 25,000 30,000
125 A 16 mm² (6 AWG) 110 mV 57,000 68,400
150 A 25 mm² (4 AWG) 110 mV 95,000 114,000
175 A 25 mm² (4 AWG) 110 mV 169,000 202,800
200 A 35 mm² (2 AWG) 110 mV 230,000 276,000
225 A 35 mm² (2 AWG) 110 mV 264,000 316,800
250 A 50 mm² (1/0 AWG) 110 mV 359,000 430,800
300 A 50 mm² (1/0 AWG) 80 mV 331,000 397,200
350 A 50 mm² (1/0 AWG) 80 mV 762,000 914,400
400 A 70 mm² (2/0 AWG) 80 mV 278,000 333,600
450 A 70 mm² (2/0 AWG) 80 mV 469,000 562,800
500 A 70 mm² (2/0 AWG) 80 mV 762,000 914,400

I²t values in A²s. Conductor sizes are Eaton's recommendation; AWG equivalents are nearest standard size and should be checked against your ampacity and voltage-drop calculation.

Common specifications across the range

  • Rated voltage 70 VDC; interrupting rating 6,000 A @ 70 VDC (TC = 2 ± 0.5 ms)
  • UL certified
  • Operating temperature −40 °C to +125 °C
  • Housing PPA; terminals matt tin-plated copper
  • Bolt centres 50.9 mm, overall length 68 mm, body height 9.9 mm; M8 bolts (8.55 mm holes)
  • Torque 20 N·m ±1
  • ISO 20934-2019 Type SF51; RoHS and ELV compliant
  • Continuous current: the 60–250 A ratings hold 100% of rating for at least 4 hours; the 300–500 A ratings are characterised at 75%. Size against actual continuous load.

In stock

EVH-125 · EVH-150 · EVH-300 · EVH-350 · EVH-400 · EVH-500

Ratings not listed above are available to order. Jonsson Tech designs, installs and commissions these systems — send us your one-line and we will size the protection with you.