{"product_id":"victron-lynx-shunt-ip22-ve-can-1000a","title":"Victron Lynx Shunt IP22 VE.Can 1000A — Whole-System Current Monitoring (Lynx)","description":"\u003cp\u003e\u003cstrong\u003eThe Victron Lynx Shunt IP22 VE.Can is a 1000A whole-system current monitor\u003c\/strong\u003e — measures total battery bank current with high precision, includes a built-in MEGA fuse holder for main bank fusing, and connects directly to your Cerbo GX via VE.Can. The right monitor when you've moved to a Lynx-based distribution system and want one integrated measurement point instead of a separate SmartShunt.\u003c\/p\u003e\n\n\u003ch2\u003eLynx Shunt vs SmartShunt — which one?\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eLynx Shunt (this product)\u003c\/th\u003e\n\u003cth\u003eSmartShunt\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eSame precision (±0.4%)\u003c\/td\u003e\n\u003ctd\u003eSame precision (±0.4%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can (faster, more bandwidth)\u003c\/td\u003e\n\u003ctd\u003eVE.Direct + Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMain bank fuse\u003c\/td\u003e\n\u003ctd\u003eBuilt-in MEGA fuse holder\u003c\/td\u003e\n\u003ctd\u003eSeparate fuse required\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModular integration\u003c\/td\u003e\n\u003ctd\u003eSnaps into Lynx Power In \/ Distributor\u003c\/td\u003e\n\u003ctd\u003eStandalone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePhone monitoring\u003c\/td\u003e\n\u003ctd\u003eVia Cerbo GX + VRM\/VictronConnect\u003c\/td\u003e\n\u003ctd\u003eDirect via Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eWhole-system installs with Lynx distribution\u003c\/td\u003e\n\u003ctd\u003eStandalone bank monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003e$355.30\u003c\/td\u003e\n\u003ctd\u003e$100–$226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChoose Lynx Shunt if:\u003c\/strong\u003e you're building a Lynx-based distribution system and want integrated measurement + main fuse in one module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose SmartShunt if:\u003c\/strong\u003e you have a single battery bank, no Lynx distribution, and want direct phone monitoring without a Cerbo GX.\u003c\/p\u003e\n\n\u003ch2\u003eWhy the Lynx Shunt IP22 VE.Can\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1000A measurement range\u003c\/strong\u003e — sized for whole-system current on large 12V\/24V\/48V banks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in MEGA fuse holder\u003c\/strong\u003e — main bank fuse integrated, accepts any MEGA fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e±0.4% measurement accuracy\u003c\/strong\u003e — same as SmartShunt and BMV-712\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVE.Can connection\u003c\/strong\u003e — high-bandwidth direct link to Cerbo GX\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue state-of-charge\u003c\/strong\u003e — counts every amp in and out for fuel-gauge accuracy\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP22 enclosure\u003c\/strong\u003e — protected against dripping water\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Lynx integration\u003c\/strong\u003e — snaps into Lynx Power In and Distributor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuxiliary inputs\u003c\/strong\u003e — temperature, midpoint voltage, or second battery monitoring\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e5-year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eCurrent measurement range\u003c\/th\u003e\n\u003ctd\u003e0–1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBattery voltage range\u003c\/th\u003e\n\u003ctd\u003e9.5–70V (12V, 24V, 48V systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eVE.Can\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBuilt-in fuse holder\u003c\/th\u003e\n\u003ctd\u003eMEGA fuse (fuse sold separately, choose by bank capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary input\u003c\/th\u003e\n\u003ctd\u003eTemperature, midpoint, or second battery voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP22 (indoor \/ dripping water resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eModular integration\u003c\/th\u003e\n\u003ctd\u003eSnaps into Lynx Power In and Lynx Distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eLYN040102000 (verify with distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years (manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRecommended applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarge residential ESS\u003c\/strong\u003e — whole-system measurement + main bank fusing in one module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine yacht with Lynx system\u003c\/strong\u003e — organized whole-bank measurement\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial backup power\u003c\/strong\u003e — telecom or small commercial 48V with Lynx distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarger off-grid homestead\u003c\/strong\u003e — integrated measurement and fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-string parallel banks\u003c\/strong\u003e — measures total current after combining at Lynx Power In\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eEvery Jonsson Tech order ships within 5 days nationwide from our Houston, Texas warehouse. MEGA fuse for the main bank sold separately — sizing depends on your bank capacity and maximum continuous current.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46133186887899,"sku":"LYN040102000","price":355.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3200\/9947\/files\/lynxshunt1000amp.jpg?v=1728731813","url":"https:\/\/www.jonssontech.net\/products\/victron-lynx-shunt-ip22-ve-can-1000a","provider":"Jonsson Tech LLC ","version":"1.0","type":"link"}