{"title":"Lynx Distributors","description":"\u003cp\u003eLynx Distributors, fuses, lynx shunt, 1000A.  \u003c\/p\u003e","products":[{"product_id":"victron-lynx-power-in-dc-busbar-m8-battery-connections","title":"Victron Lynx Power In — DC Busbar with M8 Battery Connections (Lynx System)","description":"\u003cp\u003e\u003cstrong\u003eThe Victron Lynx Power In is the entry module for Victron's modular DC distribution system\u003c\/strong\u003e — a high-current busbar with M8 bolt connections for joining multiple parallel battery strings into a single distribution point. Pairs with the Lynx Distributor and Lynx Shunt to build clean, professional, fuse-protected battery distribution systems.\u003c\/p\u003e\n\n\u003ch2\u003eWhat the Lynx System is\u003c\/h2\u003e\n\u003cp\u003eVictron's Lynx product family is a modular DC distribution kit. Instead of bolting battery cables and fuses together with whatever connectors you can find, you snap together purpose-built modules:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLynx Power In\u003c\/strong\u003e (this product) — entry point where battery strings connect\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLynx Distributor\u003c\/strong\u003e — fused outputs to inverter, MPPT, DC loads\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLynx Shunt\u003c\/strong\u003e — system-wide current measurement (replaces SmartShunt for whole-system metering)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLynx BMS\u003c\/strong\u003e — battery management for compatible LiFePO4 banks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eModules click together via positive and negative busbars, so installation is clean and inspection-friendly.\u003c\/p\u003e\n\n\u003ch2\u003eWhy use a Lynx Power In\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClean parallel battery string connection\u003c\/strong\u003e — multiple 12V\/24V\/48V strings combine at a single point\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eM8 bolt connections\u003c\/strong\u003e — standardized, secure, code-compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular design\u003c\/strong\u003e — snap into Lynx Distributor or Lynx Shunt for clean distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh current rating\u003c\/strong\u003e — designed for whole-bank current up to 1000A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspection-friendly\u003c\/strong\u003e — organized layout simplifies marine\/electrical inspection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReduces wiring chaos\u003c\/strong\u003e — eliminates ad-hoc battery cable bundles\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnection type\u003c\/th\u003e\n\u003ctd\u003eM8 bolts (battery side), modular busbar (system side)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable diameter capacity\u003c\/th\u003e\n\u003ctd\u003eUp to 22 mm via bottom guides; unlimited via side connections\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem voltage\u003c\/th\u003e\n\u003ctd\u003e12V, 24V, 48V compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax continuous current\u003c\/th\u003e\n\u003ctd\u003e1000A (system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible with\u003c\/th\u003e\n\u003ctd\u003eLynx Distributor, Lynx Shunt, Lynx BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eWall or panel mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eRobust molded enclosure, high-conductivity busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eLYN020102000 (verify with distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years (manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRecommended applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-battery-string off-grid systems\u003c\/strong\u003e — 4–8 strings of 48V LiFePO4 combined\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidential ESS\u003c\/strong\u003e — clean rack-style battery distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine multi-bank installs\u003c\/strong\u003e — organized house bank entry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial backup power\u003c\/strong\u003e — telecom, server, light industrial\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarger RV with multiple parallel batteries\u003c\/strong\u003e — clean entry-point combiner\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine inspection\u003c\/strong\u003e — inspectors love the organized layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eEvery Jonsson Tech order ships within 5 days nationwide from our Houston, Texas warehouse. The Lynx system is best designed end-to-end — send us your battery bank specs and intended distribution layout to \u003cstrong\u003esupport@jonssontech.net\u003c\/strong\u003e or call \u003cstrong\u003e346-574-9652\u003c\/strong\u003e and we'll help configure all the modules you need.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46106706608347,"sku":"LYN020102000","price":141.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3200\/9947\/files\/lynxpower.jpg?v=1728468690"},{"product_id":"victron-lynx-distributor-m10-4-fused-outputs","title":"Victron Lynx Distributor M10 — Modular DC Distribution with 4 Fused Outputs (Lynx System)","description":"\u003cp\u003e\u003cstrong\u003eThe Victron Lynx Distributor M10 is the distribution module of the Lynx system\u003c\/strong\u003e — four independently fused outputs to power your inverter\/charger, MPPT, DC loads, or anything else that draws from the battery. Each output has its own MEGA fuse holder for code-compliant, clean, organized distribution.\u003c\/p\u003e\n\n\u003ch2\u003eWhat you connect to a Lynx Distributor\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput 1\u003c\/strong\u003e — typically the largest, feeds the MultiPlus \/ Quattro inverter\/charger\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput 2\u003c\/strong\u003e — SmartSolar MPPT or other large charging source\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput 3\u003c\/strong\u003e — DC distribution panel (lights, fridge, pumps)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput 4\u003c\/strong\u003e — auxiliary or future expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach output is independently MEGA-fuse protected. If one circuit faults, the others stay live.\u003c\/p\u003e\n\n\u003ch2\u003eWhy use a Lynx Distributor\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 independent fused outputs\u003c\/strong\u003e — organized, code-compliant distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMEGA fuse holders built in\u003c\/strong\u003e — accept any MEGA fuse 50A–500A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eM10 bolt connections\u003c\/strong\u003e — heavy-duty for high-current cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular snap-fit\u003c\/strong\u003e — clicks into Lynx Power In or Lynx Shunt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspection-friendly\u003c\/strong\u003e — clean professional layout for marine surveys and electrical inspections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReduces wiring chaos\u003c\/strong\u003e — no ad-hoc fuse blocks or distribution boards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisible fuse status\u003c\/strong\u003e — quick fault diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNumber of outputs\u003c\/th\u003e\n\u003ctd\u003e4 (independent)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput fuse type\u003c\/th\u003e\n\u003ctd\u003eMEGA fuse holder (fuses sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnection type\u003c\/th\u003e\n\u003ctd\u003eM10 bolts on each output, modular busbar on system side\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem voltage\u003c\/th\u003e\n\u003ctd\u003e12V, 24V, 48V compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax continuous current per output\u003c\/th\u003e\n\u003ctd\u003ePer fuse rating (up to 500A MEGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible with\u003c\/th\u003e\n\u003ctd\u003eLynx Power In, Lynx Shunt, Lynx BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eWall or panel mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eLYN060102010 (verify with distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years (manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRecommended applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine main distribution\u003c\/strong\u003e — inverter + MPPT + house panel + bow thruster all fused\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidential ESS\u003c\/strong\u003e — distribution to MultiPlus-II + MPPT + DC subpanel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarger off-grid\u003c\/strong\u003e — multi-load distribution from main bank\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial backup\u003c\/strong\u003e — telecom rack distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSprinter conversion\u003c\/strong\u003e — clean DC distribution behind the panel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine inspection\u003c\/strong\u003e — inspectors love the clear fuse layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eEvery Jonsson Tech order ships within 5 days nationwide from our Houston, Texas warehouse. MEGA fuses sold separately — we stock the full range (60A through 500A).\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46106982842587,"sku":"LYN060102010","price":211.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3200\/9947\/files\/distributor.jpg?v=1728477416"},{"product_id":"victron-lynx-shunt-ip22-ve-can-1000a","title":"Victron Lynx Shunt IP22 VE.Can 1000A — Whole-System Current Monitoring (Lynx)","description":"\u003cp\u003e\u003cstrong\u003eThe Victron Lynx Shunt IP22 VE.Can is a 1000A whole-system current monitor\u003c\/strong\u003e — measures total battery bank current with high precision, includes a built-in MEGA fuse holder for main bank fusing, and connects directly to your Cerbo GX via VE.Can. The right monitor when you've moved to a Lynx-based distribution system and want one integrated measurement point instead of a separate SmartShunt.\u003c\/p\u003e\n\n\u003ch2\u003eLynx Shunt vs SmartShunt — which one?\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eLynx Shunt (this product)\u003c\/th\u003e\n\u003cth\u003eSmartShunt\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eSame precision (±0.4%)\u003c\/td\u003e\n\u003ctd\u003eSame precision (±0.4%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Can (faster, more bandwidth)\u003c\/td\u003e\n\u003ctd\u003eVE.Direct + Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMain bank fuse\u003c\/td\u003e\n\u003ctd\u003eBuilt-in MEGA fuse holder\u003c\/td\u003e\n\u003ctd\u003eSeparate fuse required\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModular integration\u003c\/td\u003e\n\u003ctd\u003eSnaps into Lynx Power In \/ Distributor\u003c\/td\u003e\n\u003ctd\u003eStandalone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePhone monitoring\u003c\/td\u003e\n\u003ctd\u003eVia Cerbo GX + VRM\/VictronConnect\u003c\/td\u003e\n\u003ctd\u003eDirect via Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eWhole-system installs with Lynx distribution\u003c\/td\u003e\n\u003ctd\u003eStandalone bank monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003e$355.30\u003c\/td\u003e\n\u003ctd\u003e$100–$226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChoose Lynx Shunt if:\u003c\/strong\u003e you're building a Lynx-based distribution system and want integrated measurement + main fuse in one module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose SmartShunt if:\u003c\/strong\u003e you have a single battery bank, no Lynx distribution, and want direct phone monitoring without a Cerbo GX.\u003c\/p\u003e\n\n\u003ch2\u003eWhy the Lynx Shunt IP22 VE.Can\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1000A measurement range\u003c\/strong\u003e — sized for whole-system current on large 12V\/24V\/48V banks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in MEGA fuse holder\u003c\/strong\u003e — main bank fuse integrated, accepts any MEGA fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e±0.4% measurement accuracy\u003c\/strong\u003e — same as SmartShunt and BMV-712\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVE.Can connection\u003c\/strong\u003e — high-bandwidth direct link to Cerbo GX\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue state-of-charge\u003c\/strong\u003e — counts every amp in and out for fuel-gauge accuracy\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP22 enclosure\u003c\/strong\u003e — protected against dripping water\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Lynx integration\u003c\/strong\u003e — snaps into Lynx Power In and Distributor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuxiliary inputs\u003c\/strong\u003e — temperature, midpoint voltage, or second battery monitoring\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e5-year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eCurrent measurement range\u003c\/th\u003e\n\u003ctd\u003e0–1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBattery voltage range\u003c\/th\u003e\n\u003ctd\u003e9.5–70V (12V, 24V, 48V systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eVE.Can\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBuilt-in fuse holder\u003c\/th\u003e\n\u003ctd\u003eMEGA fuse (fuse sold separately, choose by bank capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary input\u003c\/th\u003e\n\u003ctd\u003eTemperature, midpoint, or second battery voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP22 (indoor \/ dripping water resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eModular integration\u003c\/th\u003e\n\u003ctd\u003eSnaps into Lynx Power In and Lynx Distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eLYN040102000 (verify with distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years (manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRecommended applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarge residential ESS\u003c\/strong\u003e — whole-system measurement + main bank fusing in one module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine yacht with Lynx system\u003c\/strong\u003e — organized whole-bank measurement\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial backup power\u003c\/strong\u003e — telecom or small commercial 48V with Lynx distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarger off-grid homestead\u003c\/strong\u003e — integrated measurement and fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-string parallel banks\u003c\/strong\u003e — measures total current after combining at Lynx Power In\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eEvery Jonsson Tech order ships within 5 days nationwide from our Houston, Texas warehouse. MEGA fuse for the main bank sold separately — sizing depends on your bank capacity and maximum continuous current.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":46133186887899,"sku":"LYN040102000","price":355.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3200\/9947\/files\/lynxshunt1000amp.jpg?v=1728731813"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3200\/9947\/collections\/victron-lynx-distributor-dc-477401.webp?v=1728814630","url":"https:\/\/www.jonssontech.net\/collections\/lynx-distributors.oembed","provider":"Jonsson Tech LLC ","version":"1.0","type":"link"}